Medical Device Recalls
RSS ↗7,870 medical device recalls from federal enforcement feeds.
Showing 551–600 of 7,870
- Class II
Medical Device Recall · March 19, 2026
Medline medical procedure kits, containing Medline Neuro Sponges, labeled as follows: SPINAL FUSION, Medline Kit Number/SKU CDS860017AGDuring an internal review, Medline identified higher-than-expected endotoxin levels on a representative Medline neuro sponge product, indicating that in-market product may be out-of-specification for endotoxin.
- Class II
Medical Device Recall · March 19, 2026
Brand Name: DONJOY Product Name: ICEMAN, W/COLDPAD, NS, RH Model/Catalog Number: 11-9099 Software Version: No Product Description: 11-9099 - ICEMAN, W/COLDPAD, NS, RH The IceMan CLASSIC3¿ cold thDue to broken connector which may result in a temporary interruption of prescribed cold therapy.
- Class II
Medical Device Recall · March 19, 2026
Medline medical procedure kits, containing Medline Neuro Sponges (1050 in total), BIOBURDEN TEST KIT, NEURO, ROBOTIC, ACDF, ENT, etc.During an internal review, Medline identified higher-than-expected endotoxin levels on a representative Medline neuro sponge product, indicating that in-market product may be out-of-specification for endotoxin.
- Class II
Medical Device Recall · March 19, 2026
Medline medical procedure kits, containing Medline Neuro Sponges, labeled as follows: 1. RR-OMFS PACK-LF, Medline Kit Number/SKU DYNJ0045920D; 2. RR-OMFS PACK-LF, Medline Kit Number/SKU DYNJ00459During an internal review, Medline identified higher-than-expected endotoxin levels on a representative Medline neuro sponge product, indicating that in-market product may be out-of-specification for endotoxin.
- Class I
Medical Device Recall · March 19, 2026
Boston Scientific Pacemaker, Implantable Pulse Generator, Pacemaker (non- Cardiac Re-Synchronization Therapy) labeled as: 1. ESSENTIO SR SL, Model Number L100; 2. ESSENTIO DR SL Pacemaker, ModelUpdated software, Brady software maintenance release 6 (SMR6), is now available for the ACCOLADE" family of pacemakers and cardiac resynchronization therapy pacemakers (CRT-Ps)1 and the advisory population is expanding to include all CRT-P and dual-chamber extended life (DR-EL) devices. Dual chamber modes are specifically indicated for treatment of the following: " Conduction disorders that require restoration of AV synchrony, including varying degrees of AV block " VVI intolerance (i.e., pacemaker syndrome) in the presence of persistent sinus rhythm " Low cardiac output or congestive heart failure secondary to bradycardia
- Class II
Medical Device Recall · March 19, 2026
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Philips AneurysmFlow. Model Number: 001015. AneurysmFlow is a software medical device (Interventional Tool) intended to be used in combination with a Philips interventional X-ray system and 3DRA dPotential safety issue involving the Mean Aneurysm Flow Amplitude (MAFA) ratio of AneurysmFlow (Interventional Tool). Philips has determined that the MAFA ratio does not provide reliable prognostic information regarding aneurysm occlusion following Flow Diverter Stent treatment, however despite being stated in the IUF, it is being relied on for making clinical decisions.
- Class II
Medical Device Recall · March 18, 2026
Diversatek Healthcare Viper¿ 3-Stage Wire Guided Balloon Dilator, 15mm-16.5mm-18mm, REF 1205-18The catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each stage.
- Class II
Medical Device Recall · March 18, 2026
Diversatek Healthcare Viper¿ 3-Stage Wire Guided Balloon Dilator, 12mm-13.5mm-15mm, REF 1205-15The catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each stage.
- Class II
Medical Device Recall · March 18, 2026
Diversatek Healthcare Viper¿ 3-Stage Wire Guided Balloon Dilator, 18mm-19mm-20mm, REF 1205-20The catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each stage.
- Class II
Medical Device Recall · March 18, 2026
Diversatek Healthcare Viper¿ 3-Stage Fixed Wire Balloon Dilator, 6mm-7mm-8mm, REF 1204-08The catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each stage.
- Class II
Medical Device Recall · March 18, 2026
Siemens Healthcare Diagnostics, Inc.
Dimension Creatinine Flex reagent cartridge. Material Number: 10872079.Siemens Healthcare Diagnostics is recalling certain lots of Dimension Creatinine Flex reagent cartridge (Dimension CRE2) because a potential imprecision in the Dimension CRE2 quality control (QC) and patient sample results using lot numbers GA6307 and BA7005 on the Dimension System. This imprecision may lead to erroneously decreased or increased creatinine patient results
- Class II
Medical Device Recall · March 17, 2026
Custom Abutment Ti, for Straumann RC, incl. TAN screw; Catalog Number/Art.: 027.4620;A material mix-up had occurred during the manufacturing of Straumann¿ Custom Abutments. More specifically, a raw material bar of TAN-material (SAP #701924 / Lot 7130439) was incorrectly identified as a Titanium Bar Ti Gr4 D (SAP #701922 / Lot 7130430). As a result, RC Titanium abutments were manufactured using the TAN Bar material on Mill-from-Bar Machine 396-06.
- Class II
Medical Device Recall · March 17, 2026
Custom Abutment AS Ti, for Straumann RC, incl. TAN screw; Catalog Number/Art.: 010.5438;A material mix-up had occurred during the manufacturing of Straumann¿ Custom Abutments. More specifically, a raw material bar of TAN-material (SAP #701924 / Lot 7130439) was incorrectly identified as a Titanium Bar Ti Gr4 D (SAP #701922 / Lot 7130430). As a result, RC Titanium abutments were manufactured using the TAN Bar material on Mill-from-Bar Machine 396-06.
- Class I
Medical Device Recall · March 17, 2026
Medical Action Industries, Inc. 306
Medical Action Industries Inc. Pack Cath BHH, REF: BHCA49K, Sterile EO, Rx Only, QTY: 5/CaseConvenience kit contains a syringe in which the rotating adapter may unwind during use, resulting in a loose connection and/or full disconnection between the syringe and manifold"
- Class II
Medical Device Recall · March 16, 2026
Medline or Centurion medical convenience kits, containing Webcol Large Alcohol Prep Pads, labeled as: 1. NEONATAL IV START KIT (Centurion), Medline Kit SKU IV8310E; 2. IV SECUREMENT KIT (CenturioMedline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing Cardinal Health Webcol Large Alcohol Prep Pads. Cardinal Health has deemed Webcol Large Alcohol Prep Pads to be non-sterile following the discovery of a contaminant (Paenibacillus phoenicis) during a routine sterilization dose audit.
- Class II
Medical Device Recall · March 16, 2026
Centurion medical convenience kits, containing Webcol Large Alcohol Prep Pads, labeled as: LATEX FREE GENERAL PURPOSE TRAY, Medline Kit SKU 75670Medline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing Cardinal Health Webcol Large Alcohol Prep Pads. Cardinal Health has deemed Webcol Large Alcohol Prep Pads to be non-sterile following the discovery of a contaminant (Paenibacillus phoenicis) during a routine sterilization dose audit.
- Class II
Medical Device Recall · March 16, 2026
Flamingo Funnel Small, Model Number SQ20012-01Certain lots of product were associated with a manufacturing nonconformance involving use of a non-gamma sterilization compatible drape.
- Class II
Medical Device Recall · March 16, 2026
Medline and Centurion medical convenience kits, containing Webcol Large Alcohol Prep Pads, labeled as: 1. LVAD DRIVELINE KIT (Centurion), Medline Kit SKU DT17360 (Centurion); 2. LONG TERM/INPATIMedline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing Cardinal Health Webcol Large Alcohol Prep Pads. Cardinal Health has deemed Webcol Large Alcohol Prep Pads to be non-sterile following the discovery of a contaminant (Paenibacillus phoenicis) during a routine sterilization dose audit.
- Class II
Medical Device Recall · March 16, 2026
Access Total T4 Calibrator, Catalog No. 33805Beckman Coulter has identified that Access Total T4 Calibrator lots (PN 33805) exhibit a negative bias on DxI 600/800 instruments, with slopes outside product specifications. A false low patient result could cause a patient to undergo unnecessary additional diagnostic testing. A patient may be treated for a disorder not present or receive delayed treatment for hyperthyroidism. For a pregnant patient being monitored for thyroid hormone supplementation, incorrect treatment or dose may be used. A delayed patient results could cause repeat blood draw with associated complications.
- Class II
Medical Device Recall · March 16, 2026
Centurion medical convenience kits, containing Webcol Large Alcohol Prep Pads, labeled as: Universal Central/Art Line Insertion Kit, Medline Kit SKU ART155AMedline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing Cardinal Health Webcol Large Alcohol Prep Pads. Cardinal Health has deemed Webcol Large Alcohol Prep Pads to be non-sterile following the discovery of a contaminant (Paenibacillus phoenicis) during a routine sterilization dose audit.
- Class II
Medical Device Recall · March 16, 2026
Centurion medical convenience kits, containing Webcol Large Alcohol Prep Pads, labeled as: DERMATOLOGY SHAVE KIT, Medline Kit SKU SK395Medline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing Cardinal Health Webcol Large Alcohol Prep Pads. Cardinal Health has deemed Webcol Large Alcohol Prep Pads to be non-sterile following the discovery of a contaminant (Paenibacillus phoenicis) during a routine sterilization dose audit.
- Class II
Medical Device Recall · March 16, 2026
TRIGEN PROXIMAL STRAIGHT HUMERAL NAIL 8/7 X 16, REF: 71760816Humeral nail due to a manufacturing error is missing distal holes and if implanted may lead to revision surgery but, if the missing holes are identified before implantation, an equivalent backup can be used, or a bent nail of the same size, which would require additional surgical steps to address soft tissue/bone preparation, which could lead to a surgical delay of greater than 30 minutes.
- Class II
Medical Device Recall · March 16, 2026
CENTURION Circumcision Kit, Medline Kit Number/SKU CIT7050FOn lot of Sterile Circumcision Kits was distributed without the required sterilization process and is therefore not sterile.
- Class II
Medical Device Recall · March 16, 2026
Medline medical convenience kits, containing Webcol Large Alcohol Prep Pads, labeled as: 1. BLOOD CULTURE KIT, Medline Kit SKU DYNDH1520; 2. BLOOD DRAW KIT, Medline Kit SKU EBSI1317.Medline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing Cardinal Health Webcol Large Alcohol Prep Pads. Cardinal Health has deemed Webcol Large Alcohol Prep Pads to be non-sterile following the discovery of a contaminant (Paenibacillus phoenicis) during a routine sterilization dose audit.
- Class II
Medical Device Recall · March 16, 2026
Flamingo Funnel Medium, Model Number SQ20012-02Certain lots of product were associated with a manufacturing nonconformance involving use of a non-gamma sterilization compatible drape.
- Class II
Medical Device Recall · March 16, 2026
Flamingo Funnel Large, Model Number SQ20012-03Certain lots of product were associated with a manufacturing nonconformance involving use of a non-gamma sterilization compatible drape.
- Class II
Medical Device Recall · March 16, 2026
Medline and Centurion medical convenience kits, containing Webcol Large Alcohol Prep Pads, labeled as: 1. FOLEY CARE KIT, Medline Kit SKU UROT1044; 2. IV START KIT WITH EXTENSION TUBING, MedlineMedline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing Cardinal Health Webcol Large Alcohol Prep Pads. Cardinal Health has deemed Webcol Large Alcohol Prep Pads to be non-sterile following the discovery of a contaminant (Paenibacillus phoenicis) during a routine sterilization dose audit.
- Class I
Medical Device Recall · March 13, 2026
Halyard VA DETROIT CATH LAB PACK kit. Model Numbers: VMCD029.Potential risk for Medline syringe rotating adaptor unwinding during use, which may result in a loose connection and/or full disconnection between the syringe and manifold.
- Class I
Medical Device Recall · March 13, 2026
Halyard NEURO IR PERIPHERAL (PS 64405) kit. Model Number: UINR44-01.Potential risk for Medline syringe rotating adaptor unwinding during use, which may result in a loose connection and/or full disconnection between the syringe and manifold.
- Class I
Medical Device Recall · March 13, 2026
Halyard HEART CATH, SELF REGIONAL kit. Model Number: SELF131-05.Potential risk for Medline syringe rotating adaptor unwinding during use, which may result in a loose connection and/or full disconnection between the syringe and manifold.
- Class I
Medical Device Recall · March 13, 2026
Halyard CARDIAC CATH PACK SAN23CARDQ kit. Model Number: DRCC36.Potential risk for Medline syringe rotating adaptor unwinding during use, which may result in a loose connection and/or full disconnection between the syringe and manifold.
- Class I
Medical Device Recall · March 13, 2026
Halyard SAMMC ANGIOGRAPHY kit. Model Numbers: SAMM066-15.Potential risk for Medline syringe rotating adaptor unwinding during use, which may result in a loose connection and/or full disconnection between the syringe and manifold.
- Class II
Medical Device Recall · March 13, 2026
(1)(2) LeadCare¿ II Blood Lead Test Kit, (3)LeadCare¿ II 5X Blood Lead Test Kit, (4)LeadCare¿ II 9X Blood Lead Test Kit ; Catalog Number(s): (1) 70-6762, (2) 70-6762RUO, (3) 70-8404 (Box containing 5Customers reported observing unexpectedly elevated results when using certain third-party micro-collection devices to collect capillary samples for testing with the LeadCare Test Systems. False positive lead results may cause delayed results and additional unnecessary testing.
- Class I
Medical Device Recall · March 13, 2026
Halyard PERC TRAY kit. Model Numbers: SLPC34-01, SLPC34-02.Potential risk for Medline syringe rotating adaptor unwinding during use, which may result in a loose connection and/or full disconnection between the syringe and manifold.
- Class I
Medical Device Recall · March 13, 2026
Halyard CATH LAB kit. Model Number: SACL75-01.Potential risk for Medline syringe rotating adaptor unwinding during use, which may result in a loose connection and/or full disconnection between the syringe and manifold.
- Class I
Medical Device Recall · March 13, 2026
Halyard CARDIAC CATH PACK kit. Model Number: EAMC1000-05, WAFB208-02.Potential risk for Medline syringe rotating adaptor unwinding during use, which may result in a loose connection and/or full disconnection between the syringe and manifold.
- Class II
Medical Device Recall · March 13, 2026
LeadCare Ultra Blood Lead Test Kit; Catalog Number: 70-8098; The LeadCare Ultra kit is provided with the following materials: " Sensors (8 containers of 24 each; 192 tests) " Treatment Reagent TCustomers reported observing unexpectedly elevated results when using certain third-party micro-collection devices to collect capillary samples for testing with the LeadCare Test Systems. False positive lead results may cause delayed results and additional unnecessary testing.
- Class I
Medical Device Recall · March 13, 2026
Halyard CARDIAC CATH TRAY SHANDS JAX kit. Model Number: SHND401-04, SHND401-05.Potential risk for Medline syringe rotating adaptor unwinding during use, which may result in a loose connection and/or full disconnection between the syringe and manifold.
- Class I
Medical Device Recall · March 13, 2026
Halyard CATH LAB kit. Model Number: SACL75AM.Potential risk for Medline syringe rotating adaptor unwinding during use, which may result in a loose connection and/or full disconnection between the syringe and manifold.
- Class II
Medical Device Recall · March 13, 2026
LeadCare¿ Plus Blood Lead Test Kit; Catalog Number: 82-0004; The LeadCare¿ Plus kit is provided with the following materials: " Sensors (4 containers of 24 each; 96 tests) " Treatment Reagent TuCustomers reported observing unexpectedly elevated results when using certain third-party micro-collection devices to collect capillary samples for testing with the LeadCare Test Systems. False positive lead results may cause delayed results and additional unnecessary testing.
- Class II
Medical Device Recall · March 12, 2026
Siemens Medical Solutions USA, Inc
ARTIS Pheno VE30A and VE40A, Model 10849000During 3D acquisitions, lighter and darker patient images may be captured, which may result in less accurate 3D reconstruction. The variation of brightness is a result of a constant unregulated medium dose and the angular change of patient diameter caused by rotational acquisition. This may result in unintentional low-dose radiation exposure to a patient.
- Class II
Medical Device Recall · March 12, 2026
B.R.A.H.M.S PlGF Plus KRYPTOR, Catalog Number: 859075N. in vitro diagnostic test for Placental Growth FactorCustomers have observed quality control values out of range at the lowest quality control level (QC Level 1) for the PIGF assay which require troubleshooting steps to resolve. If Quality Controls are not performed according to the Instructions for Use, the underestimation of QC1 may go undetected and could contribute to falsely elevated sFlt-1/PlGF ratio results. A falsely elevated sFlt-1/PlGF ratio may result in a higher-risk classification for progression to preeclampsia with severe features potentially leading to intensified clinical monitoring.
- Class II
Medical Device Recall · March 12, 2026
LinkBio CORE Workstation, a component of the CORE Shoulder System. Product Code: 87-9136.The CORE Workstation may display an incorrect "Planning Date " when viewing cases on the "Start Case" menu screen.
- Class II
Medical Device Recall · March 12, 2026
Stryker Sustainability Solutions
Stryker Sustainability Solution Color Cuff 24" (Yellow) Quick Connect Dual Port Single Bladder REF 5921-024-235 Stryker Sustainability Solution Color Cuff 18" (Red), Quick Connect Dual Port SingleDue to potential for tourniquet cuffs to detach from the bladder at the welding connection and result in the cuff not being able to maintain pressure.
- Class II
Medical Device Recall · March 12, 2026
Healthmark Industries Co., Inc.
Mesh Style Tip Protectors CSW-03-2.0 Open-end style CSW-04-4.0 Closed-end styleProduct does not have FDA clearance.
- Class I
Medical Device Recall · March 12, 2026
Omnipod 5 Pods. Model/Catalog number: PT-001662 ASM 5PK Pod STRL OPS G6G7Due to a manufacturing defect, certain Omnipod 5 Pods from 49 lots have an internal soft cannula tear that results in insulin leaking into the Pod instead of being delivered to the user regardless of basal or bolus delivery. This defect results from damage to the unexposed portion of the soft cannula during manufacturing, which would result in a compromised fluid path. The primary failure mode is pump under-delivery due to loss of insulin to an internal leak; in some cases, the defect may also lead to pump shutoff and cessation of insulin delivery when leaked insulin contacts Pod circuity in a manner that results in an electrical short. Under-delivery of insulin (both basal and bolus insulin) or cessation of insulin put users at risk of hyperglycemia, and complications from acute and chronic hyperglycemia, including dehydration, blurry vision, nausea, vomiting, altered mental status, diabetic ketoacidosis (DKA), hyperglycemic hyperosmolar syndrome (HHS), or even death. Users may require hospitalization or medical intervention to treat severe adverse health consequences. Not all devices with the defect will issue an alarm or alert the user. If there is sufficient leakage of insulin to cause a short in the circuity, the Pod will issue a Hazard Alarm that stops all insulin delivery and alerts the user to replace their Pod. In addition, if a user s glucose is trending high and is not responding to insulin delivery, the system may reach the maximum amount of insulin microboluses allowed by the system and trigger the Automated Delivery Restriction (ADR) alert that tells users to check their blood glucose and take appropriate actions (i.e., ADR is a response to persistent hyperglycemia and maximum automated delivery constraints rather than a direct detection of the leak). The magnitude of under-delivery is unknown and based on multiple factors, including how much insulin is being delivered, whether an alarm and/or alert triggers, whether and when the user recognizes the device defect, the duration of Pod use, and the size of the tear.
- Class II
Medical Device Recall · March 12, 2026
iLet Bionic Pancreas, REF: BB1001insulin pump software versions 1.4.2, and 1.4.3 issue with Dexcom Continuous Glucose Monitoring (CGM) G7 sensor may result in delayed CGM reading then switch to non-CGM dosing, leading to only basal/requested meal doses provided, no correction doses/insulin reductions/suspensions for high/low glucose unless blood glucose entered for sensor life or replacement. Potential health risks to users include severe hyperglycemia with and without DKA and severe hypoglycemia.
- Class I
Medical Device Recall · March 11, 2026
Intuitive 8 mm SureForm 30 Gray Reloads Reference Numbers: 48230M-05 and 48230M-06Reloads for curved-tipped stapler may potentially produce an incomplete staple line.
- Class II
Medical Device Recall · March 11, 2026
Arrow Echogenic Introducer Needle REF ASK-04001-BWK2 UDI code: (01)10801902220315(17)261231(11)251210(10)33F25J0347 This device is intended for injection or aspiration of fluids. The needle protecDue to receiving a notice from a supplier that the liquid adhesive were incorrectly manufactured
- Class II
Medical Device Recall · March 11, 2026
ARROW RADIAL ARTERY CATHETERIZATION KIT REF ASK-04220-UCL1 UDI code: (01)10801902159127(17)270331(11)251203(10)33F25J0352 REF ASK-04020-EUH2 UDI code: (01)10801902213379(17)270731(11)251218(10)Due to receiving a notice from a supplier that the liquid adhesive was incorrectly manufactured