Medical Device Recalls
RSS ↗8,689 medical device recalls from federal enforcement feeds.
Showing 5,101–5,150 of 8,689
- Class II
Medical Device Recall · November 21, 2024
MEDLINE INDUSTRIES, LP - Northfield
Medline custom medical procedure kits labeled as: 1) ENDOSCOPIC SKULL BASE, REF DYNJ58648B; 2) ENDOSCOPIC SKULL BASE, REF DYNJ58648C; 3) ENT ENDO SINUS WILMINGTON PACK, REF DYNJ66447; 4) ENDOCustom convenience kits are being recall because the contain non-sterile Codman Surgical Patties & Surgical Strips, which have the potential for endotoxin contamination.
- Class II
Medical Device Recall · November 21, 2024
MEDLINE INDUSTRIES, LP - Northfield
See DocManCustom convenience kits are being recall because the contain non-sterile Codman Surgical Patties & Surgical Strips, which have the potential for endotoxin contamination.
- Class II
Medical Device Recall · November 21, 2024
MEDLINE INDUSTRIES, LP - Northfield
Medline custom medical procedure kits labeled as: 1) ENSEMBLE RACHIS-LF, REF DYNJ47568B; 2) UROLOGY ROBOTIC, REF DYNJ55555D; 3) KIT,SPINE LH, REF DYNJ906448A.Custom convenience kits are being recall because the contain non-sterile Codman Surgical Patties & Surgical Strips, which have the potential for endotoxin contamination.
- Class II
Medical Device Recall · November 21, 2024
SynchroMed II Model 8637 and SynchroMed III Model 8667 implantable pumps used with PROG CT900D CLINICIAN TABLET GLOBAL with the A810 CP app version 2.x, CFN CT900DSoftware issues were identified in application version 2.x.
- Class II
Medical Device Recall · November 21, 2024
MEDLINE INDUSTRIES, LP - Northfield
Medline custom medical procedure kits labeled as: 1) FREE FLAP BASIC SET-UP PK, REF DYNJ0991320J; 2) MVFF/FIBU #54-RF, REF DYNJ21927R; 3) FUNCTIONAL SINUS ENDOSCOPY, REF DYNJ40406A; 4) DR GOLCustom convenience kits are being recall because the contain non-sterile Codman Surgical Patties & Surgical Strips, which have the potential for endotoxin contamination.
- Class II
Medical Device Recall · November 21, 2024
MEDLINE INDUSTRIES, LP - Northfield
Medline custom medical procedure kits labeled as: 1) NEURO BASIN PACK-LF, REF DYNJ39461J; 2) NEURO BASIN KIT, REF DYNJ80200B.Custom convenience kits are being recall because the contain non-sterile Codman Surgical Patties & Surgical Strips, which have the potential for endotoxin contamination.
- Class II
Medical Device Recall · November 21, 2024
OEC 3D REF Image-Intensified Fluoroscopic X-Ray System, Mobile. The OEC 3D is a mobile fluoroscopic C-Arm imaging system used to assist trained surgeons and other qualified physicians. The systemDue to manufacturing issue of insufficient sealing of X-ray tubes and can result in a potential oil leak and loss of fluoroscopic imaging capability.
- Class II
Medical Device Recall · November 21, 2024
MEDLINE INDUSTRIES, LP - Northfield
Medline custom medical procedure kits labeled as: 1) MEM MAXILLOFACIAL PACK-LF, REF DYNJ0660040R; 2) FREE FLAP PACK-LF, REF DYNJ42833A; 3) FREE FLAP PACK-LF, REF DYNJ42833B; 4) TYMPANOPLASTY PACCustom convenience kits are being recall because the contain non-sterile Codman Surgical Patties & Surgical Strips, which have the potential for endotoxin contamination.
- Class II
Medical Device Recall · November 21, 2024
OEC 9800 REF Image-Intensified Fluoroscopic X-Ray System, Mobile. The Series OEC 9800 is designed to provide fluoroscopic and spot-film imaging of the patient during diagnostic, surgical and interDue to manufacturing issue of insufficient sealing of X-ray tubes and can result in a potential oil leak and loss of fluoroscopic imaging capability.
- Class II
Medical Device Recall · November 21, 2024
MEDLINE INDUSTRIES, LP - Northfield
Medline custom medical procedure kits labeled as: 1) CRANI, REF CDS780089V; 2) CRANIOFACIAL CDS, REF CDS780102K; 3) CRANIOFACIAL CDS, REF CDS780102L; 4) CRANIOFACIAL CDS, REF CDS780102M; 5) CRANCustom convenience kits are being recall because the contain non-sterile Codman Surgical Patties & Surgical Strips, which have the potential for endotoxin contamination.
- Class II
Medical Device Recall · November 21, 2024
SynchroMed II Model 8637 and SynchroMed III Model 8667 implantable pumps used with PROG CT900C CLINICIAN TABLET UK with the A810 CP app version 2.x, CFN CT900CSoftware issues were identified in application version 2.x.
- Class II
Medical Device Recall · November 21, 2024
OEC Elite REF Image-Intensified Fluoroscopic X-Ray System, Mobile. The OEC Elite mobile C-arm is intended to provide fluoroscopic and digital spot images of the patient anatomy, interventional tooDue to manufacturing issue of insufficient sealing of X-ray tubes and can result in a potential oil leak and loss of fluoroscopic imaging capability.
- Class I
Medical Device Recall · November 20, 2024
StatStrip Glucose Ketone Hospital Meter System. Model/Catalog Number: 63683. Prescription use blood glucose ketone meter for near-patient testingA software bug within the meter firmware leads to transmission of erroneous glucose and/or ketone patient test results to a healthcare institution's data management system (DMS) at healthcare sites using WiFi if a user navigates to the Review Results screen while the meter is in the process of transmitting the current test result to the DMS.
- Class II
Medical Device Recall · November 20, 2024
Philips Smart-Hopping 2.0 AP 1.4 GHz. Model Number: 867216The following four issues are included: 1. Certain Channel Settings may result in an Access Point preventing a connected client device from roaming to another Access Point potentially causing the client device to appear to drop out from the network. 2. if the Access Point experiences a disconnection from the Access Point Controller exceeding 4 minutes, the Access Point may not transition through the desired state to all for clean reconnection of the client radio link. 3. Potential to experience higher than expected data dropouts, device disassociations/reassociations for their wireless clients, and frequent "Loss of AP" alerts. 4. Potential for the Smart-hopping Access Point is affected by a software issue where the Access Point will resent after 82.85 days when the frame counter reaches its limit. This causes the latest synchronization check to fail and potential for loss of patient data.
- Class I
Medical Device Recall · November 20, 2024
StatStrip Glucose Hospital Meter System. Model/Catalog Number: 63685. Prescription use blood glucose meter for near-patient testing.A software bug within the Gen 2 StatStrip Hospital Meter firmware leads to transmission of erroneous glucose patient test results to a healthcare institution's data management system (DMS) at healthcare sites using WiFi if a user navigates to the Review Results screen while the meter is in the process of transmitting the current glucose test result to the DMS. The risk of this software defect is erroneously high or low glucose results being documented in a patient's medical record, which may lead to incorrect treatment.
- Class I
Medical Device Recall · November 20, 2024
StatStrip Glucose Ketone (mmol/L) Hospital Meter System. Model/Catalog Number: 63910. Prescription use blood glucose ketone meter for near-patient testingA software bug within the meter firmware leads to transmission of erroneous glucose and/or ketone patient test results to a healthcare institution's data management system (DMS) at healthcare sites using WiFi if a user navigates to the Review Results screen while the meter is in the process of transmitting the current test result to the DMS.
- Class II
Medical Device Recall · November 19, 2024
SUC-4300S, Rigid Intracardiac Sucker Fluted Tip; 1/4" (6.4mm) connector 13" (33cm) length. Indicated for handheld use only to remove excess fluid from the surgical field.Incomplete or partial pouch seals, which may result in a breach in the sterility.
- Class II
Medical Device Recall · November 19, 2024
VACUETTE SAFELINK, REF: 450210The VACUETTE SAFELINK Holder with male luer lock may leak blood due to the protective rubber sleeve bunching up and not retracting when using the device.
- Class II
Medical Device Recall · November 19, 2024
Baxter SIGMA Spectrum Infusion Pump with Master Drug Library (Version 8), Product Code 35700BAX2Devices were identified as released after repair without full testing being performed, which includes flow testing.
- Class II
Medical Device Recall · November 19, 2024
Baxter SIGMA Spectrum Infusion Pump with Master Drug Library (Version 6), Product Code 35700BAXDevices were identified as released after repair without full testing being performed, which includes flow testing.
- Class II
Medical Device Recall · November 19, 2024
Olympus Corporation of the Americas
Duravent Silicone Ventilation Tube. Model Number: 240075.Potential that Duravent Silicone Ventilation Tubes may contain incorrect product, specifically, 1.32 mm Tiny T Tubes (model: 70240076) instead of the intended Duravent Silicone Ventilation Tubes.
- Class II
Medical Device Recall · November 18, 2024
Tec 820 SEV Anesthesia Vaporizer, Reference Number 1177-9820-SEVDue to a manufacturing issue, certain Tec 6 Plus and Tec 800 series vaporizers can deliver less anesthetic agent than the vaporizer dial setting.
- Class II
Medical Device Recall · November 18, 2024
MEDLINE INDUSTRIES, LP - Northfield
HUDSON RCI mBrace, ET Tube Holder with Bite Block and 2 Point Head Strap, REF DYNJMBRC2B; tracheal tube fixation deviceComplaint defects have been noted regarding the adhesive elements of the device and the frame of the holder putting additional pressure on the patient's cheekbones and upper lip which may cause dermal injury depending on the device positioning.
- Class II
Medical Device Recall · November 18, 2024
MEDLINE INDUSTRIES, LP - Northfield
Medline procedure kits labeled as: 1) CENTRAL LINE DRESSING KIT, Reorder number DYNDC3189; dressing change trayCertain Medline kits were manufactured and distributed with Procedure Masks with SO SOFT Earloops, and SOFT TOUCH II Surgical Masks which were subsequently recalled for not meeting the bioburden testing requirements of EN 14683.
- Class II
Medical Device Recall · November 18, 2024
MEDLINE INDUSTRIES, LP - Northfield
HUDSON RCI mBrace, ET Tube Holder and 2 Point Head Strap, REF DYNJMBRC2; tracheal tube fixation deviceComplaint defects have been noted regarding the adhesive elements of the device and the frame of the holder putting additional pressure on the patient's cheekbones and upper lip which may cause dermal injury depending on the device positioning.
- Class II
Medical Device Recall · November 18, 2024
Tec 850 SEV Anesthesia Vaporizer, Reference Number 1177-9850-SEVDue to a manufacturing issue, certain Tec 6 Plus and Tec 800 series vaporizers can deliver less anesthetic agent than the vaporizer dial setting.
- Class II
Medical Device Recall · November 18, 2024
MEDLINE INDUSTRIES, LP - Northfield
Medline procedure kits labeled as: 1) SHORT TERM INFUSAPORT ACCESS KIT, Reorder number DYNDC3188; surgery trayCertain Medline kits were manufactured and distributed with Procedure Masks with SO SOFT Earloops, and SOFT TOUCH II Surgical Masks which were subsequently recalled for not meeting the bioburden testing requirements of EN 14683.
- Class II
Medical Device Recall · November 18, 2024
Tec 850 ISO Anesthesia Vaporizer, Reference Number 1177-9850-ISODue to a manufacturing issue, certain Tec 6 Plus and Tec 800 series vaporizers can deliver less anesthetic agent than the vaporizer dial setting.
- Class II
Medical Device Recall · November 18, 2024
MEDLINE INDUSTRIES, LP - Northfield
Medline procedure kits labeled as: 1) Port Access Kit, Reorder number CVI5130; 2) VANTEX 7FR 3L 20CM CVC STOCK+ BUNDLE US. Reorder number STCVC01USGV; general surgical trayCertain Medline kits were manufactured and distributed with Procedure Masks with SO SOFT Earloops, and SOFT TOUCH II Surgical Masks which were subsequently recalled for not meeting the bioburden testing requirements of EN 14683.
- Class II
Medical Device Recall · November 18, 2024
Access hsTnI Reagent, REF B52699, Immunoassay Method, Troponin Subunit. For the quantitative determination of cardiac troponin I (cTnI) levels in human serum and plasma.Beckman Coulter, Inc. is recalling their Access hsTnI assay, a medical device by correction. The reason for the recall is: high troponin antigen (>55,000 pg/mL) can contaminate an analyzers probe and cause inter-assay carryover due to insufficient washing. The contamination can cause a falsely elevated Access hsTnI result in subsequent sample(s) which can impact patient care (potentially but not limited to unnecessary coronary imaging or diagnostic catheterization) if the result is near the medical decision points.
- Class II
Medical Device Recall · November 18, 2024
Tec 820 ISO Anesthesia Vaporizer, Reference Number 1177-9820-ISODue to a manufacturing issue, certain Tec 6 Plus and Tec 800 series vaporizers can deliver less anesthetic agent than the vaporizer dial setting.
- Class II
Medical Device Recall · November 18, 2024
MEDLINE INDUSTRIES, LP - Northfield
HUDSON RCI mBrace, ET Tube Holder with 4 Point Head Strap, REF DYNJMBRC4; tracheal tube fixation deviceComplaint defects have been noted regarding the adhesive elements of the device and the frame of the holder putting additional pressure on the patient's cheekbones and upper lip which may cause dermal injury depending on the device positioning.
- Class II
Medical Device Recall · November 18, 2024
MEDLINE INDUSTRIES, LP - Northfield
HUDSON RCI mBrace, ET Tube Holder with Bite Block and 4 Point Head Strap, REF DYNJMBRC4B; tracheal tube fixation deviceComplaint defects have been noted regarding the adhesive elements of the device and the frame of the holder putting additional pressure on the patient's cheekbones and upper lip which may cause dermal injury depending on the device positioning.
- Class II
Medical Device Recall · November 18, 2024
Tec 6 Plus Anesthesia Vaporizer, Reference Numbers 1107-9601-000, 1107-9602-000, 1107-9603-000, 1107-9604-000, 1107-9610-000, 1107-9612-000, 1107-9616-000, 1107-9617-000, 2066835-001, 2069767-001, 207Due to a manufacturing issue, certain Tec 6 Plus and Tec 800 series vaporizers can deliver less anesthetic agent than the vaporizer dial setting.
- Class II
Medical Device Recall · November 18, 2024
EnVisio Patient Pad Transition Cushion, Model/Catalog Number: ENVISIO-SYS Product Description: The EnVisio Patient Pad Transition Cushion is a component of the EnVisio Navigation System which is a meThere is a potential safety risk caused by physical disassociation of the back section from the bed frame of Skytron model series 3600, 6500, 6600 and 6700 operating room beds when used with the EnVisio Navigation System.
- Class II
Medical Device Recall · November 16, 2024
Spectral CT and Spectral CT Plus. Model Numbers: 728333, 728340, 728344.Potential for a plan box not updated issue during Interventional procedure with Spectral CT that may lead to a collision with the operator or with the needle placed inside the patient, and an incorrect patient ID software issue that may lead to misdiagnosis.
- Class II
Medical Device Recall · November 15, 2024
Brand Name: K-Systems Product Name: T47 Warming Plate Model/Catalog Number: K23055 Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming anThe warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
- Class II
Medical Device Recall · November 15, 2024
mint Lesion, Software Versions: 3.10.0 and 3.10.1.Some software versions have a malfunction where they may show incorrect orientation labels for a specific subset of DICOM images.
- Class II
Medical Device Recall · November 15, 2024
Brand Name: K-Systems Product Name: Multiple/unknown Model/Catalog Number: Multiple/unknown Software Version: N/A Product Description: An electrically-powered device intended to provide suitable wThe warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
- Class II
Medical Device Recall · November 15, 2024
Brand Name: K-Systems Product Name: R65 Trolley Model/Catalog Number: K24012 Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming and/or iThe warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
- Class II
Medical Device Recall · November 15, 2024
Brand Name: K-Systems Product Name: G85 Mini Incubator Model/Catalog Number: K22074 Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming aThe warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
- Class II
Medical Device Recall · November 15, 2024
Brand Name: K-Systems Product Name: G73 Dry Bath Incubator Model/Catalog Number: K22065 Product Description: An electrically-powered device intended to provide suitable warming and/or incubation coThe warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
- Class II
Medical Device Recall · November 15, 2024
mint Lesion, Software Versions: 3.9.0 through 3.9.5.Some software versions have a malfunction where they may show incorrect orientation labels for a specific subset of DICOM images.
- Class II
Medical Device Recall · November 15, 2024
Brand Name: K-Systems Product Name: T47 Warming Plate Model/Catalog Number: K23054 Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming anThe warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
- Class II
Medical Device Recall · November 14, 2024
BD Pyxis MedStation ES 7 Drawer Auxiliary Tower, REF: 324Due to a software issue, automated dispensing cabinet devices may open the wrong cubie pocket or position, which can lead to: 1) Unintended and incorrect medication removal, or 2) Potential for a different medication (medication pulled in error) to be refilled/loaded, which may lead to may lead to low inventory or a stockout.
- Class I
Medical Device Recall · November 14, 2024
Walcott Bipolar Pencil 25 Gauge Straight. Model/Catalog Number: RX14-5011. Product Description: The Disposable Microsurgical Bipolar Pencil are designed for use in eye surgery, and other soft tissuPotential for the outer stainless-steel tube to break or detach.
- Class I
Medical Device Recall · November 14, 2024
Kirwan Surgical Products LLC Disposable 25-gauge bipolar pencil, straight, Long. Model/Catalog Number: 14-5011L The Disposable Microsurgical Bipolar Pencil are designed for use in eye surgery, andPotential for the outer stainless-steel tube to break or detach.
- Class II
Medical Device Recall · November 14, 2024
BD Pyxis MedStation ES, REF: 323Due to a software issue, automated dispensing cabinet devices may open the wrong cubie pocket or position, which can lead to: 1) Unintended and incorrect medication removal, or 2) Potential for a different medication (medication pulled in error) to be refilled/loaded, which may lead to may lead to low inventory or a stockout.
- Class I
Medical Device Recall · November 14, 2024
Optikon Bipolar Pencil 25 Gauge Straight. Model/Catalog Number: OPT14-5011. Product Description: The Disposable Microsurgical Bipolar Pencil are designed for use in eye surgery, and other soft tissPotential for the outer stainless-steel tube to break or detach.
- Class II
Medical Device Recall · November 14, 2024
BD Pyxis CII Safe ES, REF: 1116-00Due to a software issue, automated dispensing cabinet devices may open the wrong cubie pocket or position, which can lead to: 1) Unintended and incorrect medication removal, or 2) Potential for a different medication (medication pulled in error) to be refilled/loaded, which may lead to may lead to low inventory or a stockout.